WXSF-II Gas Synthesized Tester
Power supply :AC 220V ,Built-in rechargeable battery Battery performance :Charging time : 20 hours ; can work for 10 hours Purity :Accuracy:±0.5% Dew point :Response time(+20℃) H2S :Stability:0~200ppm
WXWG-V SF6 Gas Leak Detector
Power: 220V 50Hz Measurement range(SF6):0.1ppm~1000ppm(volume ratio) Indication method :LCD, digital, sound & light alarm Alarm setting range :0.1ppm~1000ppm (volume ratio) Preheating time :2 min Response time :<10S
WXWG-II SF6 Gas Leak Detector Tester
Minimum Detection Amount :1(×10-6volume ratio) Detection Range :1~1000(×10-6volume ratio) Response Time:<1 second Recovery Time:<10 seconds Display Value Error: ≤±3%
WXWS-Z Intelligent Dew Point Meter Analyzer
Dew Point Range :-80℃ — +20℃ Measuring Accuracy :±0.5℃ Moisture Range :0.05— 23100 μL/L Communication method :USB,Equipped with host computer data management software Measuring time :3-5 Minutes
WXWS-V Sf6 Dew Point Meter
Measurement range(SF6):0.1ppm~1000ppm(volume ratio) Indication method :LCD, digital, sound & light alarm Alarm setting range :0.1ppm~1000ppm (volume ratio) Preheating time :2 min Response time :<10S
WXWS-W Sf6 Dew Point Meter
Measurement range(SF6):0.1ppm~23700ppm Dew Point Precision: ±2℃ Repeatability: ±0.2℃ Gas flow: SF6 adjusted at 0.7~0.9L/min Output port: standard USB
WXFJ-II SF6 Gas Decomposition Tester
Power supply :AC 220V, Built-in rechargeable battery H2S Measuring range:0~100ppm SO2 Accuracy:±0.5% CO The minimum detectable value:≤1ppm Battery performance :Charging time : 20 hours ; can work for 10 hours
WXP-II Sf6 Portable Gas Purity Analyzer
Power supply :AC 220V ,Built-in rechargeable battery Battery performance :Charging time more than 20 hours , can use 10 hours Measuring Range :0%~100% Accuracy :±0.5% Measuring time :<2min.
WXWG-IV SF6 Gas Leak Detector
WXJD-II SF6 Density Relay Calibration Tester
Working voltage :AC220V, 50Hz Power :50W Pressure measurement resolution :0.001MPa Accuracy :0.2 Pressure measurement range :0~1MPa Storage Capacity :Save 50 test results at the same time
XP-1A Handheld Sf6 Gas Leak Detector
Power supply :DC 3V, two alkaline batteries Maximum sensitivity :R12, R22, R134a are approved by (14 g / year) Usage time of probe :About 20 hours Usage time of battery :About 30 hours under normal use Working method :Continuous, unlimited